| Mechanical
Switch |
| 14 (2) |
DPDT
Rating 4.5 Amps @ 125/250 VAC |
| 16 (2) & 55 (4) |
V3 SPDT
Rating 10 Amps @ 125/250 VAC, 0.5 Amps @ 125 VDC |
| 17 (2) |
V3 SPDT Gold Plated
Contacts
Rating 1 Amp @ 125 VAC, 0.5 Amps @ 30 VDC |
| Reed Type
Proximity Switch |
| 25 (2) & 58 (4) |
SPDT Maxx-Guard
Rating – Volts Max. 500 V AC/DC, Current Max.
3 Amps, Power Max. 100 Watts/VA, Min. 3 Watts |
| 40 (2) & 59 (4) |
SPST Maxx-Guard
Rating 0.15 Amps @ 30 VDC |
| Inductive
Proximity Sensor |
| 33 (2) |
SST Dual Module Normally
Open
Rating 0.3 Amps @ 125 V AC/DC |
| 34 (2) |
SST Dual Module Normally
Closed
Rating 0.3 Amps @ 125 V AC/DC |
| 42 (2) & 52 (4) |
2-Wire or 3-Wire
V3
E.g. 2-Wire Namur – Current Rating Target On :
< 1 mA Target Off : > 3 mA, Nominal Voltage 8
VDC /
3-Wire PNP or NPN – Rating 100 mA @ 60 VDC |
| 43 (2) |
2-Wire or 3-Wire
Cylindrical or Slotted
E.g. 2-Wire Namur – Current Rating Target On :
< 1 mA Target Off : > 3 mA, Nominal Voltage 8
VDC /
3-Wire PNP or NPN – Rating 100 mA @ 60 VDC |
| 44 (2) |
SST Namur Dual Module
Current Rating Target On : < 1 mA Target Off : >
3 mA, Voltage Range 6 to 29 VDC |
| Position Transmitter
|
| 70 (1) |
4 to 20 mA Output
Loop Powered (Resistive Type)
Supply Voltage 8 to 28 VDC, Linearity Error <1% of
Full Scale
Option – HART Protocol |
| 71 (1) |
4 to 20 mA Output
Loop Powered (Capacitive Type)
Supply Voltage 12 to 30 VDC |
| 72 (1) |
Digital Output Bus
Powered (Resistive Type) – FOUNDATION Fieldbus
/ Profibus PA Supply Voltage 9 to 32 VDC |
| 74 (1) |
4 to 20 mA Output
Loop Powered (High Performance Resistive Type)
Supply Voltage 8 to 28 VDC, Linearity Error <0.5%
of Full Scale |
| Bus Communication |
| 92 |
DeviceNet Module
2 x Discrete Inputs, Open & Closed / 2 x Power Outputs
(Solenoids) 24 VDC, 4 Watts / 1 x 4 to 20 mA Auxiliary
Input |
| 93 & 94 |
FOUNDATION Fieldbus
Module
Function 93 (Bus Powered) - 2 x Discrete Inputs, Open
& Closed / 2 x Discrete Outputs (Piezo) 2mA @ 6.5
VDC each
Function 94 (Externally Powered) - 2 x Discrete Inputs,
Open & Closed / 2 x Power Outputs (Solenoids) 4
Watts Total Combined, Current Limited to 200mA |
| 95 |
Modbus Module
2 x Discrete Inputs – Open & Closed / 2 x
Power Outputs (Solenoids) 10 to 24 VDC / 1 x 4 to 20
mA Auxiliary Input |
| 96 & 97 |
AS-Interface Module
Function 96 (31 Devices per Network) - 2 x Sensor Inputs
– Open & Closed / 2 x Auxiliary Inputs / 2
x Power Outputs (Solenoids) 25 to 30 VDC, 4 Watts
Function 97 w/Extended Addressing (62 Devices per Network)
- 2 x Sensor Inputs – Open & Closed / 2 x
Auxiliary Inputs / 1 x Power Outputs (Solenoids) 25
to 30 VDC, 4 Watts **Other Functions Available
On Request |